danaxprofits.blogg.se

Simulation of low frequency system on cst microwave studio
Simulation of low frequency system on cst microwave studio











  1. #Simulation of low frequency system on cst microwave studio update
  2. #Simulation of low frequency system on cst microwave studio full
  3. #Simulation of low frequency system on cst microwave studio software

Improved convergence for problem scenarios with many ports. Repaired inductance calculation of a single coil for the magnetoquasistatic transient solver.ĬST EM STUDIO - LF Frequency Domain Solver (Tetrahedral Mesh)ĭisplay the abscissa of admittance matrix in project units.

#Simulation of low frequency system on cst microwave studio full

Improved stability if the feature "Perform full integration close to structure" is activated in combination with multiple near field sources.Īdded missing output of total solver memory.įixed issue with rays transmitting through opaque materials for some geometries.ĬST EM STUDIO - LF Time Domain Solver (Tetrahedral Mesh) Improved stability if visual ray output is activated in combination with SBR solver. Improved error checking in solver initialization.įixed incomplete ray visualization with Ray Tube solver. Repaired farfield calculation for higher order NFS imprint for more than one NFS.Ĭharacteristic Mode Analysis: Support of remote calculation. Improved radiated power calculation and directivity calculation for very large antennas. Improved robustness for local multi-layer with eCFIE and low-frequency stabilization. Improved error handling for sensitivity calculation in general purpose solver.ĬST MICROWAVE STUDIO - Integral Equation Solverįixed farfield calculation for solids whose material properties are described by a surface impedance. In rare cases, the wave impedance of waveguide ports became the reference impedance for post-processing and schematic, instead of the line impedance. Repaired thread pinning error when parallelization is deactivated on single socket machines.ĬST MICROWAVE STUDIO - Frequency Domain Solver (Tetrahedral Mesh) Surface impedance with roughness curve not updated after a frequency change.Ĭorrected sign error in active impedance from combine results.Īvoid false error message when linking derivatives to backward compatibility signals under Linux OS.įixed multi-gpu performance issue on Linux OS.įixed instability problem in case dispersive materials are touching open boundary.Īdded missing mode scaling factor in power calculation for simultaneous excitations.ĬST MICROWAVE STUDIO - Transient Solver (TLM Mesh)įixed uneven S-Parameter sampling in final results when intermediate results have been generated. Robustness of recovery after network failure or Main Controller restart has been improved.įixed wrong run ids in optimizer log files for evaluations with outer mesh adaptation. Robustness of file transfer has been improved.

#Simulation of low frequency system on cst microwave studio update

Information about mesh moving status is now preserved.Ĭreating of archives when using result cache with distributed computing has been fixed.ĭetection of installed service packs for the automatic update mechanism of DC has been fixed (installed service packs were not correctly recognized by the Main Controller).įixed filename and path conversion for projects with non-ASCII characters. The CHT solver can now be chosen in a Block Simulation task.įixed solver choice synchronization after switching to certain solvers in a 3D simulation project.Ĭorrected component type reading in odb++ import.Īdded button to remove already defined ports.įixed incorrect material import under certain circumstances. Improved vector Description of unit cell port modes. Update custom unit and label correctly when using Field calculator. If only 'Move mesh on parameter change if possible' is changed in the special mesh properties dialog, the results will no longer be deleted.įixed instability when shutting down CST STUDIO SUITE when 3D results of a Block Simulation Task are displayed.Ĭopy individual color of solid on transform with copy.Īnalytical Curve dialog box is now resizable.Īdded missing new line after 4 data pairs in TOUCHSTONE export for more than four ports. New Feature!Įrror output in log file improved when no connection between AutoUpdate and GUI can be established. Implemented support of cgroups under Linux OS. Various improvements to Component Library. The 2017 release builds further on CST's synthesis and simulation capabilities, with new features for filter design, interference analysis and multiphysics simulation.

#Simulation of low frequency system on cst microwave studio software

The electromagnetic simulation software CST STUDIO SUITE® is the culmination of many years of research and development into the most accurate and efficient computational solutions for electromagnetic designs in a wide range of frequencies - static to optical. The latest edition includes a range of new tools for synthesis and analysis and improvements to existing features. Computer Simulation Technology (CST) announces the update of the 2017 version of the electromagnetic simulation tool, CST STUDIO SUITE.













Simulation of low frequency system on cst microwave studio